MUT LIMITER - Turbulent viscosity limiter
Limit the maximum value of turbulent viscosity μT
to be no more than some multiple of the freestream laminar viscosity
(μL)∞.
More specifically:
Max(μT) ≤ integer * 1000 * (μL)∞
Suggested range is 50 < integer < 100.
This keyword is not valid with the Chien or Rumsey-Gatski
k-ε models. Use
K-E MAXIMUM TURBULENT VISCOSITY
instead.