INITIALIZE - Initialize in grid direction

Structured Grids

INITIALIZE [ALONG] [PLUS|MINUS] {I|J|K} [LINES] [zone_selector]

By default, in a new (i.e., non-restart) run, the direction for the initial velocity is determined by the information specified with the FREESTREAM and ARBITRARY INFLOW keywords. For structured grids, the INITIALIZE keyword may be used to specify that the initial velocity is in the ±i, ±j, or ±k direction. The magnitude of the initial velocity is unchanged.

Note that one of I, J, or K must be specified, and that the PLUS direction is the default.

See Also: FREESTREAM, ARBITRARY INFLOW