BOYLES LAW LAB
- Set up apparatus as shown.

- Open the valve and pull the plunger up so the end is at 10cc.
- Close the valve.
- Place 3N into the weight can and read the volume of air in the
chamber
- Record the volume to the nearest tenth of a cc in the data
chart.
- Add 3 more newtons to the weight can and record the new
volume.
- Repeat adding 3N at a time and recording volume. Continue up
to 42N.
- Draw a graph plotting pressure in N vs. Volume in cc using a
spread sheet or graphing computer program.
- State Boyles Law as determined through your data analysis.
Back
Please send any comments to:
Web Related:
Steven.Gutierrez@grc.nasa.gov