| nb |
| A number from 1 to 4 indicating which boundary to initialize
| |
1 | | for j = 1
| |
2 | | for j = jmax
| |
3 | | for k = 1
| |
4 | | for k = kmax
|
|
|
| ixs |
| Integer indicating method for specifying the axial location
to start the boundary layer:
| |
1 | | to specify the i index
| |
2 | | to specify the x station
|
|
|
| str |
| i index or x location to start the
boundary layer, depending on the value of ixs
|
|
| igrs |
| Integer indicating method for specifying the initial height of
the boundary layer:
| |
1 | | to specify the number of grid points from the wall
| |
2 | | to specify the thickness
| |
3 | | to compute thickness from initial x station
|
|
|
| delt |
| Number of grid points in boundary layer (if igrs = 1),
or boundary layer thickness (inches) (if igrs = 2)
|
|
| nbli |
| Integer indicating type of boundary layer and whether to keep
constant thickness or grow with x
| |
1 | | Turbulent profile, growing with x
| |
-1 | | Turbulent profile, constant thickness
| |
2 | | Laminar profile, growing with x
| |
-2 | | Laminar profile, constant thickness
|
|
|
| nzone |
| Zone number for initialization
| |
0 | | All zones
| |
> 0 | | Zone nzone only
|
|
A flat plate temperature distribution will also be constructed
consistent with the wall temperature boundary condition of either
adiabatic or constant temperature wall.
Note: BL_INIT cannot currently do more than one boundary
in each zone without over-writing itself.