M2129 Duct Grid s_duct03.cgd, 3 zones -- VGs model specified # Freestream conditions: # Mach Pres Temp Alpha Beta Freestream total 0.74 14.667 517. 0.0 0.0 # Boundary Conditions # Inflow Boundary Arbitrary inflow Total Hold_totals Zone 1 uniform 0.74 14.667 517. 0.0 0.0 Endinflow # Outflow Boundary (psi) Downstream pressure 12.63 zone 3 Turbulence spalart Max_Wall_Distance 30 Grid_Units Cfl# mode 2 cfl increment 0.025 2.0 1.5 100 500 Cycles 2000 print frequency 10 Iterations per cycle 5 # Algorithm limiters DQ limiter on drmax 0.1 dtmax 0.1 Grid limiter angle 150 # Vortex Generators VORTEX GENERATOR MODEL BAY ZONE 2 NUMBER 11 VANE_SPEC 13 23 35 36 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 58 59 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 81 82 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 104 105 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 127 128 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 150 151 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 173 174 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 196 197 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 219 220 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 242 243 27 50 KX -0.000001 0.1225 10.0 VANE_SPEC 13 23 265 266 27 50 KX -0.000001 0.1225 10.0 ENDVORTEX Loads print planes frequency 10 zone 3 surface i 34 mass normal -1 Endloads Test 150 2 Test 199 Test 194 Test 200 1