Tribometers, Liquid Lubrication
Surface Science Branch
NASA Glenn Research Center
Cleveland, Ohio 44135
-
FOUR-BALL VACUUM TRIBOMETER
-
Vacuum Range: Ambient (Air, Inert) to 1E-7 Torr
-
Speed: 10 to 500 RPM
-
Load: 50-1032 N
-
Temperature: Room
-
Specimens: 3/8" Diameter Bearing Balls
-
Motion: Sliding (Most Accelerated Testing)
-
BALL-ON-PLATE VACUUM TRIBOMETER
-
Vacuum Range: Ambient (Air, Inert) to 1E-9 Torr
-
Speed: 1-100 RPM
-
Load: Up to 440 N
-
Temperature: Room
-
Specimens: 1/2" Diameter Bearing Balls - 2 Flat 2" Diameter Plates
-
Motion: Rolling Sliding
-
GOES-BEARING VACUUM TRIBOMETER
-
Vacuum Range: Ambient (Air, Inert) to 1E-9 Torr
-
Speed: Continuous 1-1200 RPM or Dither Mode
-
Load: Up to 220 N
-
Temperature: 20-70 °C
-
Specimens: 1219 Size Angular Contact Bearings
-
Motion: Rolling (Actual Mechanism)
-
HIGH-TEMPERATURE PIN-ON-DISK TRIBOMETER
-
Atmosphere: Dry Air or Dry Nitrogen
-
Speed: 10-100 RPM
-
Load: 5-20 N
-
Temperature: 20 to 700 °C
-
Specimens: 3/8" Balls - 2 1/2" Disk
-
Motion: Sliding
-
BALL-ON-DISK TRIBOMETER
-
Atmosphere: Dry Air or Dry Nitrogen
-
Speed: 1-100 RPM
-
Load: 1-10 N
-
Temperature: Room
-
Specimens: 1/4 to 3/8" Balls - 1" Disk
-
Motion: Sliding
-
PARCHED ELASTOHYDRODYNAMIC BEARING APPARATUS
-
Atmosphere: Ambient or Dry Air
-
Speed: 1000 - 7000 RPM
-
Load: 200 - 1000 N
-
Temperature: 20 °C
-
Specimens: Type 7808 Angular Contact Ball Bearings
-
Motion: Rolling
Return to Tribology
& Surface Science Branch Home Page
NASA GRC Privacy
Policy
. . . Last updated April 11, 2001 -fsh
. . . Last edited August 12, 2003 -pba